LL GLOBAL UA
ZW32-40.5

ZW32-40.5

Outdoor high-voltage vacuum circuit breaker

Outdoor vacuum circuit breaker with solid-insulated embedded poles for 40.5 kV overhead distribution networks. It switches load, overload and short-circuit currents and is maintenance-free over its service life.

Key parameters

Rated voltage
40.5 kV
Rated current
630/1250/1600 A
Rated short-circuit breaking current
20/25/31.5 kA
Mechanical endurance
10,000 operations
Weight
270 kg

General information

The ZW32-40.5 outdoor high-voltage vacuum circuit breaker features an original design with integrated solid-insulated poles (embedded contacts) and a highly reliable operating mechanism. The device is mainly used in medium-voltage overhead distribution networks for making and breaking load currents, overload currents and short-circuit currents.

  • Extremely high reliability.
  • Completely maintenance-free throughout its service life.
  • High mechanical and electrical endurance.
  • Small dimensions and weight, easy installation.

Service conditions

  • Ambient air temperature: −30 °C … +60 °C.
  • Altitude: not more than 3000 m.
  • Wind speed: not more than 34 m/s.
  • Vibration or ground motion from outside the switchgear and controlgear can be neglected.
  • Pollution level: IV.
  • Storage temperature: −40 °C … +85 °C.

Main technical parameters of the circuit breaker

ParameterUnitValue
Rated voltagekV40.5
Rated currentA630/1250/1600
Rated frequencyHz50 or 60
Power-frequency withstand voltage, 1 min (wet / dry): phase-to-phase, phase-to-earth / across open gapkV80 95/95
Lightning impulse withstand voltage (peak): phase-to-phase, phase-to-earth / across open gapkV185
Rated short-circuit breaking currentkA20/25/31.5
Rated short-circuit making current (peak)kA63/80
Rated peak withstand currentkA63/80
Short-time withstand current (4 s)kA25/31.5
Rated operating sequenceO – 0.1 s – CO – 3 s – CO – 6 s – CO – 60 s (reset)
Number of rated short-circuit current breaking operationstimes30
Mechanical enduranceoperations10000
Operating mechanism control voltageVAC/DC 220
Power-frequency withstand voltage of secondary circuits (1 min)kV2

Main mechanical parameters of the circuit breaker

ParameterUnitValue
Contact stroke (gap)mm16 ± 1
Contact overtravelmm3 ± 0.5
Opening speedm/s1.4–1.8
Closing speedm/s0.4–0.8
Contact bounce time on closingms≤ 5
Phase spacing (between pole centres)mm560 ± 2
Non-simultaneity of three-phase closing/openingms≤ 2
Main circuit resistance per phaseµΩ< 80
Closing timems≤ 100
Opening timems≤ 50
Weightkg270

Overall and mounting dimensions of the circuit breaker

Detail views: mounting holes of the upper and lower terminals for 630–1250 A.

All products