LL GLOBAL UA

Products

Key parameters for each item. Full data tables and drawings are in the PDF catalogue.

Download cataloguePDF, 9 MB, in Ukrainian

SF6 circuit breakers

LW36-126

LW36-126

Outdoor high-voltage AC SF6 circuit breaker

Outdoor SF6 circuit breaker with self-blast arc quenching and spring-operated mechanism for 126 kV, 50 Hz networks. It switches rated and short-circuit currents for line control and protection and can also serve as a bus-coupler breaker.

Rated voltage
126 kV
Rated current
3150 A
Rated short-circuit breaking current
40 kA
Operating mechanism
spring-operated
Mechanical endurance
10,000 operations
Request a quote
LW38-252

LW38-252

Self-blast SF6 circuit breaker

Three-phase outdoor SF6 circuit breaker for 252 kV, 50 Hz substations and transmission lines. It makes and breaks rated and short-circuit currents and supports fast auto-reclosing.

Rated voltage
252 kV
Rated current
4000 A
Rated short-circuit breaking current
40 kA
Rated operating sequence
O – 0.3 s – CO – 180 s – CO
Mechanical endurance
5,000 operations
Request a quote
LW30-72.5(126)T/T3150-40

LW30-72.5(126)T/T3150-40

Dead-tank SF6 circuit breaker

Outdoor dead-tank SF6 circuit breaker with built-in current transformers and spring-operated mechanism for 72.5 (126) kV, 50 Hz networks. Suited to new and refurbished substations, including seismic regions and cold climates.

Rated voltage
72.5 / 126 kV
Rated current
3150 A
Rated short-circuit breaking current
40 kA
Built-in CT primary current
300 … 2000 A
Mechanical endurance
10,000 cycles
Request a quote

Disconnectors and earthing switches

GW4

GW4

Outdoor three-phase disconnector

GW4 series outdoor disconnectors for opening and closing energised lines under no-load conditions. Each pole has two rotating porcelain insulator columns with a horizontal centre-break blade.

Rated voltage
40.5; 72.5; 145; 220; 330; 500 kV
Rated current
630 … 3150 A
Altitude
up to 4500 m
Request a quote
GW7-72.5

GW7-72.5

Outdoor three-column double-break disconnector

Outdoor three-phase, three-column double-break disconnector with earthing switch for 72.5 kV networks. Used to switch lines under no-load conditions and to provide visible isolation of equipment under maintenance from live parts.

Rated voltage
72.5 kV
Rated current
2000 A
Rated short-time withstand current
40 kA
Rated frequency
60 Hz
Operating mechanism
motor-operated
Request a quote
GN19-12 · GN19-12C

GN19-12 · GN19-12C

Indoor high-voltage disconnector

Indoor disconnectors for AC networks of 12 kV and below, 50 Hz. Operated by a CS6-1 manual mechanism to open and close energised circuits under no-load conditions; version C is a wall-bushing type.

Rated voltage
12 kV
Rated current
400; 630; 1000; 1250 A
Short-time withstand current (4 s)
12.5 … 40 kA
Operating mechanism
manual, CS6-1
Request a quote
GN30-12 · GCD-12 · GW9-12

GN30-12 · GCD-12 · GW9-12

High-voltage disconnector range

Range of 12 kV disconnectors: GN30-12 indoor rotary disconnector and GCD-12 and GW9-12 outdoor disconnectors.

Rated voltage
12 kV
Request a quote

Current and voltage transformers

LB7-110 · LB7-110W2

LB7-110 · LB7-110W2

Oil-immersed current transformer

Oil-immersed current transformer with capacitor-graded oil-paper insulation for current measurement, energy metering and relay protection in 110 kV, 50 or 60 Hz networks. Two transformation ratios are selected by reconnecting links outside the expansion tank.

Rated voltage
110/√3 kV
Highest voltage for equipment
126/√3 kV
Rated primary current
2×50 … 2×1000 A
Rated secondary current
1 or 5 A
Request a quote
TYD110/√3-0.02-H

TYD110/√3-0.02-H

Capacitor voltage transformer

Outdoor capacitor voltage transformer for voltage and power measurement, automation and relay protection in 50 Hz HV and EHV networks; also serves as a coupling capacitor for power-line carrier communication. A fast-saturating reactor damper effectively suppresses ferroresonance.

Rated voltage
110/√3 kV
Rated capacitance
0.02 µF
Rated frequency
50 Hz
Specific creepage distance (H version)
≥ 25 mm/kV
Request a quote
JDJ2-35

JDJ2-35

Oil-immersed voltage transformer

Single-phase oil-immersed 35 kV voltage transformer with porcelain housing for voltage measurement and supplying metering and protection circuits.

Rated voltage ratio
35/0.1 kV
Accuracy class / rated output
0.2 — 100 VA; 0.5 — 150 VA; 1.0 — 200 VA; 3 — 500 VA
Thermal limiting output
1000 VA
Porcelain housing creepage distance
81 cm
Request a quote
PT / CT

PT / CT

Voltage and current transformers

Range of cast-resin and oil-immersed voltage and current transformers, plus high-voltage metering units, for indoor and outdoor installation.

Request a quote

Surge arresters and fuses

Y5W, HY10WZ

Y5W, HY10WZ

Polymer-housed metal-oxide surge arresters for AC systems

Gapless metal-oxide surge arresters in polymer (composite) housing. Connected in parallel with line and substation equipment to protect it against lightning and switching overvoltages.

System nominal voltage
35; 66; 110; 220 kV
Nominal discharge current
5 / 10 kA
Rated arrester voltage
54 … 200 kV
Long-duration current impulse (2 ms rectangular)
400 / 800 A
Request a quote
MOA

MOA

Metal-oxide surge arresters

Zinc-oxide (metal-oxide) surge arresters for AC generation, transmission and distribution systems up to and including 220 kV. They limit lightning and switching overvoltages and form the basis of equipment insulation coordination.

System voltage
up to 220 kV
System frequency
50 ± 2 Hz or 60 ± 2 Hz
Request a quote
RW12 · RW12-15 · RW12-35 · RW33-15 · RW12-15F

RW12 · RW12-15 · RW12-35 · RW33-15 · RW12-15F

Drop-out fuse cutouts

Outdoor high-voltage drop-out fuses and load-break drop-out fuses, installed on the HV side of distribution transformers or on line tee-offs to protect against short circuits and overloads. On operation the fuse carrier drops open, providing a visible isolating gap.

Request a quote
RW12-15

RW12-15

RW12-15 drop-out fuse cutout

Outdoor RW12-15 drop-out fuse cutout protecting distribution transformers and overhead line tee-offs at 12(15) kV against short circuits and overloads.

Rated voltage
12(15) kV
Rated current
100 / 200 A
Rated short-circuit breaking current
8; 12.5; 16 kA (100 A); 12.5; 16 kA (200 A)
Rated lightning impulse withstand voltage
125 kV
Creepage distance
330 mm
Request a quote
RW12-35

RW12-35

RW12-35 drop-out fuse cutout

Outdoor RW12-35 drop-out fuse cutout protecting distribution transformers and overhead line tee-offs at 35 kV against short circuits and overloads.

Rated voltage
35 kV
Rated current
100 / 200 A
Rated short-circuit breaking current
12.5; 16 kA
Rated lightning impulse withstand voltage
170 kV
Creepage distance
875 mm
Request a quote
RW33-15

RW33-15

RW33-15 drop-out fuse cutout

Outdoor RW33-15 drop-out fuse cutout protecting distribution transformers and overhead line tee-offs at 12(15) kV against short circuits and overloads. Fitted with a pressure-relief cap for increased breaking capacity.

Rated voltage
12(15) kV
Rated current
100 / 200 A
Rated short-circuit breaking current
12.5; 16 kA
Rated lightning impulse withstand voltage
125 kV
Creepage distance
330 mm
Request a quote
RW12-15F

RW12-15F

RW12-15F drop-out fuse cutout with arc chute

Outdoor RW12-15F drop-out fuse cutout protecting distribution transformers and overhead line tee-offs at 12(15) kV against short circuits and overloads. An arc chute made of flame-retardant ABS confines and de-ionises the arc.

Rated voltage
12(15) kV
Rated current
100 / 200 A
Rated short-circuit breaking current
12.5; 16 kA
Rated lightning impulse withstand voltage
125 kV
Creepage distance
330 mm
Request a quote
HY5W · HY5WR · HY5WZ · HY5WS · HY1.5W

HY5W · HY5WR · HY5WZ · HY5WS · HY1.5W

Surge arresters

Range of surge arresters for distribution networks, substations and low-voltage distribution systems.

Request a quote

Power transformers

SCB10, SCB13

SCB10, SCB13

Cast-resin dry-type transformers

Three-phase dry-type power transformers with epoxy-resin cast windings and foil LV winding. Designed for sites with stringent fire-safety requirements and indoor power distribution systems.

HV voltage class
10 kV
LV voltage
0.4 kV
Rated power
30 … 2500 kVA
Vector group
Yyn0, Dyn11
Short-circuit impedance
4 % / 6 %
Request a quote

Switchgear

ZCW10-126

ZCW10-126

Outdoor compact hybrid switchgear (open-type)

Open-type compact switchgear assembly with air external insulation and SF6 arc quenching for control and protection of three-phase 126 kV networks. The circuit breaker, current transformers and busbars are integrated on a common steel structure, requiring only 30–50 % of the area of a conventional layout.

Rated voltage
126 kV
Rated current
1250 A
Rated short-time withstand current
40 kA
Short-circuit duration
4 s
Bay width
3.3 m (standard)
Request a quote
KYN28-12

KYN28-12

Metal-clad withdrawable switchgear

Indoor metal-clad switchgear with withdrawable vacuum circuit breakers for three-phase 3.6–12 kV, 50 Hz systems. Used for receiving and distributing power and for control, protection and monitoring of circuits, with full mechanical and electrical interlocking.

Rated voltage
3.6; 7.2; 12 kV
Rated current
630 … 3150 A
Rated short-circuit breaking current
20; 25; 31.5; 40 kA
Enclosure degree of protection
IP4X
Request a quote
KYN61-40.5 · HXGN15-12 · HXGN17-12 · XGN66-12 · SRM16-12 · XGN-12 · TBBZ-12 · DFW-12 · DFWK-12

KYN61-40.5 · HXGN15-12 · HXGN17-12 · XGN66-12 · SRM16-12 · XGN-12 · TBBZ-12 · DFW-12 · DFWK-12

Medium-voltage switchgear and cable distribution cabinets

Switchgear range including metal-clad withdrawable units, compact and gas-insulated ring main units, fixed-type cubicles, plus a reactive power compensation unit and cable distribution cabinets.

Request a quote
GGD (GGD1, GGD2, GGD3)

GGD (GGD1, GGD2, GGD3)

Low-voltage AC distribution switchboard

Fixed-type low-voltage switchboards for 380 V, 50 Hz AC systems in power plants, substations and industrial facilities, used for power distribution and control of power, lighting and distribution equipment.

Rated voltage
380 V
Rated current
up to 3150 A
Rated short-circuit breaking current
15 / 30 / 50 kA
Installation
indoor
Request a quote

Vacuum circuit breakers

ZW32-40.5

ZW32-40.5

Outdoor high-voltage vacuum circuit breaker

Outdoor vacuum circuit breaker with solid-insulated embedded poles for 40.5 kV overhead distribution networks. It switches load, overload and short-circuit currents and is maintenance-free over its service life.

Rated voltage
40.5 kV
Rated current
630/1250/1600 A
Rated short-circuit breaking current
20/25/31.5 kA
Mechanical endurance
10,000 operations
Weight
270 kg
Request a quote
ZW32-12F · ZW32-12FG

ZW32-12F · ZW32-12FG

Intelligent outdoor vacuum sectionalising circuit breaker

Vacuum circuit breaker installed at the customer boundary point or on a tee-off of a 12 kV overhead feeder. It automatically isolates faults in the customer network (short circuits, single-phase earth faults) so that the rest of the feeder stays energised.

Rated voltage
12 kV
Rated current
630; 1250 A
Rated short-circuit breaking current
20; 25 kA
Mechanical endurance
10,000 cycles
Weight
approx. 70 kg
Request a quote
ZN63A(VS1)-12

ZN63A(VS1)-12

Indoor high-voltage vacuum circuit breaker

Indoor vacuum circuit breaker for three-phase 12 kV, 50 Hz networks, used for protection and control of utility and industrial equipment. Integrated breaker and operating mechanism, available in fixed or withdrawable (truck) versions.

Rated voltage
12 kV
Rated current
630 … 2500 A
Rated short-circuit breaking current
20; 25; 31.5; 40 kA
Mechanical endurance
20,000 cycles
Request a quote

Load break switches

FW-630A

FW-630A

Pole-mounted SF6 load break switch

SF6-insulated pole-mounted load break switch for 12/24/40.5 kV overhead distribution lines, switching load and overload currents and able to automatically sectionalise a faulted line section. Manual, motor and remote operation via an electronic controller.

Rated voltage
12 / 24 / 40.5 kV
Rated current
630 A
Short-time withstand current
20 kA / 1 s
Insulating and arc-quenching medium
SF6 gas
Degree of protection
IP65
Request a quote
FZW32-40.5/T1250-25

FZW32-40.5/T1250-25

Outdoor vacuum load break switch with disconnector

Outdoor vacuum load break switch with mechanically linked disconnector for three-phase 40.5 kV, 50 Hz networks. Arc interruption takes place in vacuum interrupters, and a visible isolating gap is formed on opening.

Rated voltage
40.5 kV
Rated current
1250 A
Rated mainly active load breaking current
1250 A
Rated short-time withstand current
25 kA (4 s)
Mechanical endurance
10,000 cycles
Request a quote
FKN12-12 · FKRN12-12

FKN12-12 · FKRN12-12

Indoor air-blast (puffer) load break switch

Indoor 12 kV load break switch with compressed-air (puffer) arc quenching, switching load, closed-loop, transformer magnetising and charging currents. FKRN12-12 is a switch-fuse combination capable of interrupting any current up to the short-circuit current.

Rated voltage
12 kV
Rated current
630 A (FKN12-12); 100 A (FKRN12-12)
Rated short-time withstand current
20 kA (4 s)
Rated short-circuit breaking current (FKRN12-12)
31.5 kA
Request a quote
FZ(R)N25-12 · JN15-12/31.5 · JN22-40.5/31.5 · JN22B-40.5/31.5

FZ(R)N25-12 · JN15-12/31.5 · JN22-40.5/31.5 · JN22B-40.5/31.5

Load break switches and earthing switches

Range comprising the FZ(R)N25-12 vacuum load break switch and the JN15-12, JN22-40.5 and JN22B-40.5 indoor high-voltage earthing switches.

Request a quote

Prefabricated substations

YB□-12/0.4

YB□-12/0.4

Outdoor prefabricated substation (European type)

Prefabricated transformer substation combining HV switchgear, power transformer and LV switchboard in one enclosure. Used in urban distribution networks, industrial and infrastructure facilities and for temporary power supply.

Rated voltage HV / LV
12 / 0.4 kV
HV-side protection
load break switch + fuse combination
Transformer
hermetically sealed oil-immersed S9/S10/S11 or dry-type
Request a quote
YB□-12

YB□-12

Pad-mounted compact substation (American type)

American-type pad-mounted compact transformer substation; presented in the catalogue with photographs of available versions.

Request a quote

Insulators and bushings

CW(L)B · CWW(L) · FGWB · PD · XP · XWP · S(C) · ZSW · ZS · ZW · ZA · ZB · ZC · ZD · ZL · LXP

CW(L)B · CWW(L) · FGWB · PD · XP · XWP · S(C) · ZSW · ZS · ZW · ZA · ZB · ZC · ZD · ZL · LXP

Wall bushings and insulators

Indoor and outdoor wall bushings, pin insulators, porcelain and toughened-glass cap-and-pin suspension insulators, line post insulators, and indoor and outdoor station post insulators.

Request a quote